Product Overview
The ASI Rheumatoid Factor (RF) Direct Slide Test Kit by Arlington Scientific is a rapid latex slide agglutination assay designed for the qualitative and semiquantitative determination of rheumatoid factor (RF) in human serum. This diagnostic test supports laboratory evaluation of rheumatoid factor antibodies, which may be associated with rheumatoid arthritis and other autoimmune conditions. The assay utilizes latex particles coated with purified human gamma globulins to produce visible agglutination in the presence of rheumatoid factor, with results available in approximately 2 minutes.
Designed for professional in vitro diagnostic use, the ASI RF Direct Slide Test requires no initial dilution of serum samples for qualitative testing. The 100-test kit includes RF latex reagent, glycine-saline solution, reactive and nonreactive liquid controls, disposable stirrer pipets, and six-well test cards. The assay is standardized against a World Health Organization (WHO) reference preparation and offers a manufacturer-stated shelf life of up to 24 months. All reagents require refrigerated storage at 2–8°C (35.6–46.4°F) and must not be frozen.
Product Features
- Rapid Testing: Produces visible latex agglutination results in approximately 2 minutes.
- Qualitative and Semiquantitative Testing: Supports rheumatoid factor detection and estimation of antibody concentrations through serial dilution.
- Simple Testing Procedure: No initial serum dilution is required for qualitative testing.
- WHO-Standardized Assay: Calibrated against a World Health Organization reference preparation for rheumatoid factor testing.
- Visual Agglutination Method: Uses latex particles coated with purified human gamma globulins for RF antibody detection.
- Quality Controls Included: Supplied with reactive and nonreactive liquid controls to verify assay performance.
- Convenient Kit Configuration: Includes reagents, glycine-saline diluent, disposable stirrer pipets, and test cards for laboratory testing.
- Extended Shelf Life: Manufacturer reports up to 24 months of shelf life from the date of manufacture when properly stored.
- Professional Diagnostic Use: Intended for use by qualified healthcare and laboratory personnel.
Product Specifications
| SKU/Catalog Number | MF-700100DC |
| Product Type | Rheumatoid Factor Latex Agglutination Test Kit |
| Product Name | ASI RF Direct Slide Test |
| Brand | ASI |
| Manufacturer | Arlington Scientific, Inc. |
| Test Name | Rheumatoid Factor (RF) Test |
| Test Method | Latex Slide Agglutination |
| Detection Target | Rheumatoid Factor (RF) |
| Specimen Type | Human Serum |
| Result Type | Qualitative and Semiquantitative |
| Reading Method | Visual Agglutination |
| Test Time | Approximately 2 Minutes |
| Analytical Sensitivity | 8.0 IU/mL |
| Specificity | Greater Than 95% (Manufacturer Stated) |
| Standardization | WHO Reference Preparation |
| Initial Sample Dilution | Not Required for Qualitative Testing |
| RF Direct Latex Reagent | 4.0 mL |
| Reactive Control | 1.0 mL |
| Nonreactive Control | 1.0 mL |
| Glycine-Saline Solution | 100 mL |
| Disposable Stirrer Pipets | 100 (0.05 mL) |
| Test Cards | 17 Disposable 6-Well Test Cards |
| Storage Requirements | Refrigerated |
| Storage Temperature | 2–8°C (35.6–46.4°F) |
| Special Handling | Store all reagents upright. Do not freeze. Allow reagents and serum samples to reach 20–30°C (68–86°F) before testing. Do not heat reagents in a water bath. Pipets and test cards do not require refrigeration. |
| CLIA Classification | Moderate Complexity (Non-Waived) |
| FDA 510(k) Number | K821319 |
| CPT Code | 86430 |
| Intended Use | Professional In Vitro Diagnostic Use |
| Shelf Life | Up to 24 Months From Date of Manufacture |
| Country of Origin | United States |
| Packaging | 1 Kit/Box |
| Quantity per Package | 100 Tests/Kit |